Talk on PFD and P&ID Development for UM Chem Eng Students| NO. | EQUIPMENT TYPE | DETAILS SHOWN ON PFD | DETAILS SHOWN ON P&ID |
|---|---|---|---|
| 1 | Separator/Vessel |
Tag No. Name/Service Sizing Criteria: - Operating pressure & temperature - Capacity Design Info: - ID x T/T - Design pressure & temperature |
Tag No. Name/Service Design Info: - ID x T/T - Design pressure & temperature - Internals - Materials - Design Code - Vessel Trim |
| 2 | Column |
Tag No. Name/Service Sizing Criteria: - Operating pressure & temperature - Capacity - Product Specification e.g. Dry Gas Water Content for Glycol Contactor) Design Info: - ID x T/T - Design pressure & temperature |
Tag No. Name/Service Design Info: - ID x T/T - Design pressure & temperature - Internals - Materials - Design Code - Vessel Trim |
| 3 | Compressor (provide for each stage) |
Tag No. Name/Service Sizing Criteria: - Suction pressure & temperature - Discharge pressure - Capacity Design Info: - Operating power - Design pressure & temperature |
Tag No. Name/Service Design Info: - Operating power at suction/discharge pressure - Design pressure & temperature |
| 4 | Pump |
Tag No. Name/Service Sizing Criteria: - Capacity at differential head (for centrifugal pump) - Capacity at differential pressure (for positive displacement pump) Design Info: - Absorbed power - Design pressure & temperature |
Tag No. Name/Service Design Info: - Installed/rated motor power - Design pressure & temperature - Capacity at diff head (or pressure) |